·Electromagnetic force locking 500N ·Adopt a small plane "electromagnetic" locking structure. ·Support 16 to 20 cascaded connections. ·Design of permanent magnet in matcher ·Small body, simple installation ·Full-angle eye-catching indicator light ·No abrasive powder will be produced. ·IP65/IP67 protection |
▊D3SL-T/RFID Series Selection Table
Locking mode | deploy | model | Output mode | coded system |
Electromagnetic locking | normalized form | D3SL-T-DB-N2 | NPN | universal coding |
D3SL-T-DB-N1 | NPN | Unique coding | ||
D3SL-T-DB-P2 | PNP | universal coding | ||
D3SL-T-DB-P1 | PNP | Unique coding | ||
Advanced type | D3SL-T-DG-N2 | NPN | universal coding | |
D3SL-T-DG-N1 | NPN | Unique coding | ||
D3SL-T-DG-P2 | PNP | universal coding | ||
D3SL-T-DG-P1 | PNP | Unique coding |
▊Technical parameters of D3SL-T/RFID
type | Hinged door | ||
small-sized | |||
M12 connector | |||
normalized form | High functional type | ||
working distance | Sao(off-0n) | 4mm | |
Sar(on-0ff) | 4mm | ||
Response time | Lock → release | 155ms | |
Release → lock | 155ms | ||
Detection → Non-detection | 20ms+2ms* (Number of cascaded connections -1) | ||
Non-detection → detection | 300ms+25ms* (Number of cascaded units -1) | ||
Control output (OSSD output) | Output mode | Transistor output "2 | |
Maximum load current | 150mA | ||
Residual voltage (on) | Maximum ?2.5V (when the cable is 5m) and 3.5V (when the cable is 31m). | ||
OFF voltage | Maximum ?2.0V (when the cable is 5m) and 3.0V (when the cable is 31m). | ||
leakage current | Up to 0.5mA | ||
Maximum load capacity | 0.8uF | ||
Load connection resistance | Max. 2.5 Euro | ||
AUX output (Non-safety system output) | Output mode | Transistor output | |
Maximum load current | 50mA | ||
Residual voltage (ON) | Maximum 2.5V (when the cable is 5m) and 3.5V (when the cable is 31m). | ||
external input (Short-circuit current) | Safety input | About 1.5 max 2 | |
Locking control input OSSD action switching input | About 2.5 mA | ||
Reset /EDM input | About 5mA (high functional type only) | ||
EDM select input | About 2.5 mA (high functional type only) | ||
Power Supply | Power supply voltage | 24 VDC 10% including ripple (P-P)10% Class2 | |
consumed power | <5W | ||
protective circuit | Reverse connection protection of power supply, short circuit protection of outputs, surge protection of outputs and reverse connection protection of outputs. | ||
Environmental resistance | Enclosure protection grade | IP65/67(IEC60529) | |
Operating ambient temperature | 20 degrees below zero to 55 degrees without freezing. | ||
Storage ambient temperature | 25 degrees below zero to 70 degrees without freezing. | ||
Using ambient humidity | 5% to 95%RH | ||
Storage environment humidity | 5% to 95%RH | ||
Vibration resistance | 10 to 55 Hz, double amplitude 2.0 mm, X, Y and Z directions for 5 minutes (IEC60947-5-3 | ||
Applicable standards | ENISO13849-1:2015(PLe,Category4), IEC60947-5-3,EN60947-5-3 |
▊Model description of safety switch
▊hookup
Standard type (NPN, cascade) | Standard (PNP, cascade) |
Standard type (NPN, cascade) | |
Standard (PNP, cascade) |
Functional (NPN, cascade) | Functional (PNP, cascade) |
"Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection "1. Use EDM and reset: wiring as shown in the figure. 2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V. 3. Only use EDM: Turn off the EDM selection (pink line). K1.K2: External equipment (forced guided relay, electric and magnetic contactor, etc.) S: reset switch | "Open and close linkage, purple is connected with +24V; Locking linkage purple disconnection "1. Use EDM and reset: wiring as shown in the figure. 2. Do not use EDM and reset: connect EDM selection (pink line) and reset /EDM (light color recording) to 0V. 3. Only use EDM: Turn off the EDM selection (pink line). K1.K2: External equipment (forced guided relay, electromagnetic contactor, etc.) S: reset switch |
High functional type (NPN, cascade) | |
"Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection 1. Use EDM and reset: wiring as shown in the figure. 2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to +24V; 3. Only use EDM: Turn off the EDM selection (pink line). K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.) S: reset switch | "Open and close linkage, purple is connected to 0V; Locking linkage purple disconnection 1. Use EDM and reset: wiring as shown in the figure. 2. Do not reset EDM: Select EDM (chalk line) and reset /EDM (light green) to+24V; 3. EDM only: Turn off the EDM selection (chalk line). K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.) S: reset switch |
Functional (PNP, cascade) | |
Open and close linkage, purple connected to +24V; Locking linkage purple disconnection 1. Use EDM and reset: wiring as shown in the figure. 2. Do not use EDM and reset: connect EDM (pink line) and reset /EDM (light green) to OV; 3. Only use EDM: Turn off the EDM selection (pink line). K1,K2: External equipment (forced-guided dimensional appliances, electromagnetic contactors, etc.) S: reset switch | Open and close linkage, purple connected to +24V; Locking linkage purple disconnection *1. Make ?EDM and reset: wire as shown in the figure. 2. Do not reset EDM: Select EDM (chalk line) and connect reset /EDM (light green) to 0V; 3. EDM only: Turn off the EDM selection (chalk line). K1,K2: External equipment (forced guided relay, electromagnetic contactor, etc.) S: reset switch |
▊Indication of indicator light
▊Product ruler diagram
▊Selection Method of Safety Switch D3SL-T/RFID Series
Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.
E-Mail: info@lh-safety.com
Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai
(Greenland East Coast International Plaza-Room A 313)
Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd. ICP19034341-1 Technical Support: lanjujing