·Universal shell: 22.5mm universal shell, with strong versatility in appearance and size. ·Three-proof paint coating on the circuit board: protect the circuit board from moisture, insulation, water and dust, and prevent parts from loosening to meet G3 anti-corrosion standards. ·Convenient wiring: the power supply is represented by red and black, the input terminal is represented by S plus number, and the input terminal is represented by number. ·All-localization: All-localization devices are adopted, with high cost performance and worry-free quality. ·Support a variety of equipment input: emergency stop button, safety door, PNP safety light curtain, expansion module. |
▊ | technical parameter |
rated insulation voltage
picture | |||
model | SM-C-101 | SM-C-104 | |
Power supply characteristics | |||
supply voltage | 24V DC / A | 24V DC | |
Voltage tolerance | 0.85 ~ 1.1 | / | |
voltage range | / | 20~30V DC | |
Current loss | ≤90mA (24V DC); ≤240mA (24V AC | ≤70mA (24V DC) | |
Input feature | |||
incoming current | ≤50mA (24V DC) | ≤70mA (24V DC) | |
conductor resistance | ≤15 | ≤15Ω | |
input device | Emergency stop button, safety door, PNP safety light curtain | Safety switch, contact switch | |
Output characteristics | |||
Number of contacts | 3NO + 1NC | 4NO + 2NC | |
Contact material | AgSnO2 + 0.2μm Au | AgSnO2 + 0.2 μm Au | |
Safe output | / | 13, 14, 23, 24, 33, 34, 43, 44 | |
Auxiliary output | / | 11, 12 (status indication); Y1, Y2 (fault feedback) | |
Contact type | / | Forced orientation | |
Output characteristics | |||
Contact fuse protection | 10A gL/gG, NEOZED (normally open contact) 6A gL/gG, NEOZED (normally closed contact) | 10A gL/gG, NEOZED (normally open contact) 6A gL/gG, NEOZED (normally closed contact) | |
Electric shock mechanical life | 107 Secondary or higher | 107 Secondary or higher | |
Switching capacity (EN60947-5-1) | AC-15, 5A/230V; DC-13, 5A/24V | AC-15, 5A/230V; DC-13, 5A/24V | |
Time characteristics | |||
Suction buffer time | ≤300ms | ≤30ms | |
Release buffer time | ≤30ms | ≤20ms | |
recovery time | ≤100ms | ≤100ms | |
Short-term interruption of power supply | 20ms | 20ms | |
Environmental characteristics | |||
electromagnetic compatibility | EN 60947, EN 61000-6-2, EN 61000-6-4 | ||
frequency of oscillation | 10Hz~55Hz | ||
Vibration amplitude | 0.35mm | ||
usage temperature | -20℃~+60℃ | ||
storage temperature | -40℃~+85℃ | ||
relative humidity | 10%~90% | ||
altitude | ≤2000m | ||
Insulation characteristics | |||
Overvoltage grade | Ⅲ | ||
class of pollution | 2 | ||
250V AC | |||
Rated impulse voltage | 6000V (1.2/50us) | 6000V (1.2/50us) | |
Rated impulse voltage | 1500V AC, 1min | ||
Electrical clearance and creepage distance | accord with EN 60947-1 | ||
認證 | |||
safety integrity level | SIL3 | ||
Performance grade | PLe | ||
Security category | Cat.4 |
▊functional block diagram
model | SA101 | SA104 |
functional block diagram |
▊ | Typical application |
model | SM-C-101 | SM-C-104 |
Typical application |
Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.
E-Mail: info@lh-safety.com
Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai
(Greenland East Coast International Plaza-Room A 313)
Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd. ICP19034341-1 Technical Support: lanjujing