SM-602 programmable safety controller

As the most important part of safety loop, safety controller/safety PLC has been recognized by more and more people, but in the process of use, there are still many users who are confused about the differences between safety relay and ordinary relay, so I would like to share them with you here. As we all know, we must remember three words in the concept of safety design:

(1) Redundancy

(2) Difference

(3) Self-detection


   How to construct the safety loop with the reliability above PLd, the safety controller must become an important link. The safety loop consists of safety input, safety control and safety output subsystems, and the safety control "including safety relay, safety controller, safety PLC, etc." realizes the safety control function. Designers match different safety controllers to achieve the reliability level of the safety loop according to the number of products at the input end.


SM-602 programmable safety controller

1720164449995785.png

Is a configurable safety controller, which supports the input of various safety product components.

Maximum support for 6 sets of dual-loop inputs.

2-way safety relay output

4-channel semiconductor safety output, expandable output module

Modbus protocol communicationInput and output fault indicator light

Safety certification: PL e, Cat: 4


Product selection

product name

Type number

Safe input

Output

Brand

Safety controller

SM-602

6CH

2NO+4SO

LHS

explain

Up to 6 sets of dual-channel safety products can be entered.

Safety grating, emergency stop, safety door lock, reset, etc.

Official website programming software download connection: http://lhsafety.com.cn/showinfo-257-118-0.html








safety performance

? Performance level (PL): PL e

? Security category (Cat.): Cat.4

? Mission time (TM): 20 years

? Diagnostic coverage (DC/DC avg): 99%

? Safety Integrity Level (SIL): SIL3

? Hardware Fault Margin (HFT): 1

? Safe Failure Score (SFF): 99%

? Probability of dangerous failure (PFH d): 1.78E-9/h

? Stop Category: 0/1

Complies with standard EN ISO13849

Complies with standard EN ISO13849

Complies with standard EN ISO13849

Complies with standard EN ISO13849

Conforms to standards IEC61508, IEC62061

Conforms to standards IEC61508, IEC62061

Conforms to standards IEC61508, IEC62061

Conforms to standards IEC61508, IEC62061

Complies with standard EN 60204-1


Main technical parameters

Power supply 

characteristics

·Power supply voltage: 24VDC

·Voltage range: 20~30VDC

·Current loss: ≤110mA(24VDC)

Input characteristics

·Input current: ≤10mA(24VDC)

·Conductor resistance: ≤15Ω

·Input equipment: emergency stop button, safety door, two-hand button safety light curtain, magnetic safety switch, etc.

·Input channel: 6

Relay output 

characteristics

·Number of contacts: 2NO (safety output)

·Contact material: AgSnO2

·Contact fuse protection: 10A is fast, 6A is slow.

·Switching capacity: 5A/230VAC;; 5A/24VDC

Semiconductor output characteristics

·Number of contacts: 4SO (safety output)

·Contact fuse protection: 10A is fast, 6A is slow.

·Switching capacity: 2A/24VDC

Time characteristic

·Suction buffer time: ≤100ms

·Release buffer time: ≤30ms

·Recovery time:

         Emergency stop operation: ≤30ms

         Power failure: ≤1000ms

·Recovery time:

         Emergency stop operation: ≤30ms

         Power failure: ≤100ms

·Short-term power interruption: 20ms

Communication 

characteristics

·Baud rate: 38.4kbps (fixed)

·Communication length: ≤1000m

·Networking capacity: ≤10 units


Environmental characteristic parameters

·Electromagnetic compatibility: comply with EN60947, EN61000-6-2 and EN61000-6-4.

·Vibration frequency: 10Hz~55Hz

·Vibration amplitude: 0.35mm

·Service temperature: -20℃~+60℃

·Storage temperature: -40℃~+85℃

·Relative humidity: 10%~90%

·Overvoltage grade: Ⅲ

·Pollution level: 2

·Altitude: ≤2000m

·Rated isolation voltage: 250VAC.

·Rated impulse voltage: 6000V(1.2/50us)

·Insulation strength: 1500VAC, 1min.

·Electrical clearance and creepage distance: in accordance with EN60947-1.

1666333314320610.png


Functional application parameters

functional block diagram

Typical application

圖片3.png

圖片4.png


Input element: CH1 (emergency stop button); CH2 (emergency stop button); CH3 (reset button)

Input element: CH4 (emergency stop button); CH5 (emergency stop button); CH6 (reset button)

Control logic: CH1&CH2CH4&CH5

Reset mode: manual reset output delay: 0s.

Safety level: Cat.4 performance level: PLe safety integrity level: SIL 3


Wiring diagram

Power Supply 

1.png

correspondence

1655948458157829.png

input

3.png4.png5.png
6.png7.png
9.png10.png

reset

11.png12.png

feedback

13.png14.png

output

15.png16.png17.png


Related Products
Download
PDF file download
Video file download
Previous

Contact us

400-881-6062

Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

E-Mail: info@lh-safety.com

Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

(Greenland East Coast International Plaza-Room A 313)

Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

Online service

Online message

  • Click to refresh
  • 主站蜘蛛池模板: 亚洲av无码第一区二区三区| 大地资源网在线观看免费官网| 1000部精品久久久久久久久| 中文字幕免费在线观看动作大片 | 久久精品国产清自在天天线| 欧美艳星nikki激情办公室 | 精品人妻伦九区久久aaa片| 熟女少妇色综合图区| 久久久久亚洲av无码专区首| 精品超清无码视频在线观看| 成 人 免费 黄 色 视频| 秋霞在线观看秋| 国产色婷婷五月精品综合在线| 欧美xxxx做受性欧美88| 亚洲成aⅴ人片久青草影院| 亚洲av人无码激艳猛片| 三级做a全过程在线观看 | 久久频这里精品99香蕉| 国产又大又硬又粗| 国产精品免费福利久久| 国产精品美女www爽爽爽视频| 国产18禁黄网站免费观看| 99热在线观看| 中文字幕av无码不卡免费| 亚洲精品无码不卡av| 四虎影视永久地址www成人| 午夜免费福利小电影| 高清无码一区二区在线观看吞精| 国产精品无套内射迪丽热巴| 国产爆乳无码一区二区麻豆| 久久亚洲av成人无码| 狠狠噜天天噜日日噜| 成人免费无遮挡在线播放| 国精产品一区一区三区| 国产精品乱码久久久久久软件| 欧洲美女熟乱av| 成人色网站| 国产精品18久久久久久vr| 各处沟厕大尺度偷拍女厕嘘嘘| 香港三级日本三级a视频 | 成年女人永久免费看片|